Reliable 300CU Use and Care Manual Page 17

  • Download
  • Add to my manuals
  • Print
  • Page
    / 56
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 16
13
CLEANING AND MAINTENANCE
EMPTYING AND CLEANING THE INSIDE OF THE BOILER TANK
IMPORTANT: Clean the boiler tank at least once every month so as to remove any
scale residues which might affect the normal operation of the appliance.
Switch off the appliance
Bleed out any pressure remaining in the boiler tank (L) using the steam button
(A) on the gun (C), pointing the jet into a suitable container.
Unplug it from the main power and leave it to cool before cleaning out the
boiler tank, so as to avoid the risk of scalds.
Slowly unscrew the boiler tank filler cap (M) and remove it completely.
Slowly add tap water to the boiler tank (L) to prevent any spurts of steam;
shake the appliance and turn it upside down to empty it. Repeat the operation
several times.
WARNING: Never add scale removers, vinegar or other perfumed substances to
the tank, as these risk damaging the appliance with immediate cancellation of the
warranty.
TROUBLESHOOTING
No steam comes
out of the nozzle
The nozzle is
dispensing little
steam
Problem Check Possible Causes Possible Remedy
Steam ready light
(H) off
Steam ready light
(H) on
Steam ready light
(H) on – Water in
the boiler tank (L)
Steam lock (B)
Steam ready light
(H) on
Cold boiler tank
No water in the
boiler tank (L)
Malfunction
In use locked
Cold boiler tank
Steam regulation
dial (K) set to
minimum
Wait for the
steam ready light
to switch on (H)
Refill the tank, as
described in the
paragraph
“INSTRUCTIONS
FOR USE”
Contact an assis-
tance centre
Unlock
Wait for the
boiler tank (L) to
heat up
Use the relevant
dial (K) to regu-
late the steam
Page view 16
1 2 ... 12 13 14 15 16 17 18 19 20 21 22 ... 55 56

Comments to this Manuals

No comments